    Default MC4VA over travel reset

    I picked up an Okuma MC4VA in good working condition a month ago with an OSP 5000M-G control. During transport the bed slid forward and now I am getting an over travel fault. I took off the apron and moved the bed manually however the readout on the panel stayed the same. The prox on the bed seems to be working properly and is not engaged now.
    My theory is its past the factory over travel resets in the operating system. How do I go in and reset these? Manual doesn’t show this.

  2. #2
    Join Date
    Jun 2012
    Location
    Michigan
    Posts
    4,468
    Post Thanks / Like
    Likes (Given)
    4064
    Likes (Received)
    2649

    Default

    If this is what I think it is, there is a button in the back panel. Hold that down while someone moves the table off the limits.