Hi guys
My 1995 LB 25 that I have moved and has been sitting for one year I just powered up and was facing some bar was running for an hour fine. I moved the x in the user parameters and it was fine for a wile then it stoped with the alarm 100-3 Dif over x-axis 5F6B or 5BB9 or 5F60 or 544A. So what I found is that it will single block the programme at 50 percent but not at 70 percent.
And not in auto with movement. Is there some FIX for the DIF over X axis.
The X has around 50 to 60 load going up and 10 or so going down.
Any suggestions would be appreciated.
Thanks Collector
My 1995 LB 25 that I have moved and has been sitting for one year I just powered up and was facing some bar was running for an hour fine. I moved the x in the user parameters and it was fine for a wile then it stoped with the alarm 100-3 Dif over x-axis 5F6B or 5BB9 or 5F60 or 544A. So what I found is that it will single block the programme at 50 percent but not at 70 percent.
And not in auto with movement. Is there some FIX for the DIF over X axis.
The X has around 50 to 60 load going up and 10 or so going down.
Any suggestions would be appreciated.
Thanks Collector