Problems when sending .min files back to osp5000 control - it misses random chars.
Close
Login to Your Account
Likes Likes:  0
Results 1 to 8 of 8
  1. #1
    Join Date
    Feb 2018
    Country
    DENMARK
    Posts
    54
    Post Thanks / Like
    Likes (Given)
    2
    Likes (Received)
    62

    Default Problems when sending .min files back to osp5000 control - it misses random chars.

    Hey

    I got a problem with my DNC - i use cimco and i have no problem sending from the okuma to the pc but when i want to send them back there will be missing some chars.. it seems random and not very easy to locate.

    here is an example of the program on the pc and what it looks like when its on the control again.


    PC Program that i send to the Okuma(it was made on the okuma and send to the pc for backup)

    The rest text is what's missing - i see no pattern..

    Code:
    $M20.MIN%
    N0001 G00 X   500     Z    50     M157
    N0002 G50                         S1000
    N0100 G97                         S1404 M42 M03 M08
    N0101 G00 X    34     Z     3     T010101
    N0102 G96                         S 150
    N0103 G85 N0104 D 2     F 0.2   U 2     W 0.1
    N0104 G81
    N0105 G00 X    20
    N0106 G01             Z     0     G42 E 0.2
    N0107                 Z  -146
    N0108 G02 X    28     Z  -150     I 4
    N0109 G01 X    32                 E 0.3
    N0110 G40
    N0111 G80
    N0112 G00 X    34
    N0113 G97                         S1404 M09
    N0114     X   500     Z    50     T0100
    N0200 G97                         S1872 M08 M03 M157
    N0201 G00 X    34     Z     3     T020202
    N0202 G96                         S 200
    N0203 G87 N0204
    N0204 G81
    N0205 G00 X    20
    N0206 G01             Z     0     G42 F 0.22
    N0207                 Z  -146     F 0.16
    N0208 G02 X    28     Z  -150     I 4
    N0209 G01 X    32
    N0210 G40
    N0211 G80
    N0212 G00 X    34
    N0213                 Z     3
    N0214 G97                         S1872 M09
    N0215     X   500     Z    50     T0200
    N0300 G97                         S1273 M08 M03 M157
    N0301 G00 X    34     Z     3     T030303
    N0302 G71 X    16.932 Z   -60     H 3.068 D 0.2   U 0.1   B 60     F 2.5   M22 M73 M32
    N0303                             M05 M09
    N0304 G00 X   500     Z    50     T0300
    N0305 M02
    %

    Here is the same program ive send to the okuma..

    Code:
    $A.MIN%
    N0001 G00 X   500     Z    50     M157
    N0002 G50                         S1000
    N0100 G97                         S1404 M42 M03 M08
    N0101 G00 X    34     Z     3     T010101
    N0102 G96                         S 150
    N0103 G85 N0104 D 2     F 0.2   U 2     W 0.1
    N0104 G81
    N0105 G00 X    20
    N0106 G01             Z     0     G42 E 0.2
    N0107                 Z  -146
    N0108 G02 X    28     Z  -150     I 4
    N0109 G01 X    32                 E 0.3
    N0110 G40
    N0111 G80
    N0112 G00 X    34
    N0113 G97                         09
    N0114     X   500     Z    50     T0100
    N0200 G97                         S1872 M08 M03 M157
    N0201 G00 X    34     Z     3     T020202
    N0202 G96                         S 200
    N0203 G87 N0204
    N0204 G81
    N0205 G00 X    20
    N0206 G01             Z     0     .22
    N0207                 Z  -146     F 0.16
    N0208 G02 X    28     Z  -150     I 4
    N0209 G01 X    32
    N0210 G40
    N0211 G80
    N0212 G00 X    34
    N0213                 Z     3
    N0214 G97                         S1872 M09
    N0215     X   500     Z    50     T0200
    N03                     S1273 M08 M03 M157
    N0301 G00 X    34     Z     3     T030303
    N0302 G71 X    16.932 Z   -60     H 3.068 D 0.2   U 0.1   B 60     F 2.5   M22 M73 M32
    N0303                             M05 M09
    N0304 G00 X   500     Z    50     T0300
    N0305
    %

  2. #2
    Join Date
    Jun 2012
    Location
    Michigan
    Posts
    4,316
    Post Thanks / Like
    Likes (Given)
    3840
    Likes (Received)
    2543

    Default

    2 things to look at.
    Is the baud rate the same?
    Have you tried getting rid of all spaces?

  3. #3
    Join Date
    Feb 2018
    Country
    DENMARK
    Posts
    54
    Post Thanks / Like
    Likes (Given)
    2
    Likes (Received)
    62

    Default

    I tryed adjusting the rate but that dident work at all.. and i put pause after each line is send.. no change..

    I will try removing the spaces when i get to the machine again.. i am pretty sure we tryed it yesterday with no luck - but i will give it a go again.

  4. #4
    Join Date
    May 2005
    Location
    Ohio
    Posts
    409
    Post Thanks / Like
    Likes (Given)
    20
    Likes (Received)
    115

    Default

    On my Okumas with the OSP5000L control I use a tape emulator because of characters dropping. I had Okuma application specialists and our Cimco rep trying all kinds of things to get it to transfer without losing characters.
    The Cimco DNC guy recommended this... ADR BTR forOkuma OSP5000with Sanyo 2302 Tape Reader
    Little expensive but works great.

    My Okumas with 5000L-G or newer control does not need the emulator...just the 5000L and older machines.

  5. #5
    Join Date
    Feb 2006
    Location
    Minneapolis
    Posts
    200
    Post Thanks / Like
    Likes (Given)
    8
    Likes (Received)
    25

    Default

    Try slowing down the baud rate.

  6. #6
    Join Date
    Feb 2018
    Country
    DENMARK
    Posts
    54
    Post Thanks / Like
    Likes (Given)
    2
    Likes (Received)
    62

    Default

    Quote Originally Posted by BobM3 View Post
    Try slowing down the baud rate.
    As i wrote in previous post.. already tryed that.

  7. #7
    Join Date
    Feb 2018
    Country
    DENMARK
    Posts
    54
    Post Thanks / Like
    Likes (Given)
    2
    Likes (Received)
    62

    Default

    Quote Originally Posted by bradleyk View Post
    On my Okumas with the OSP5000L control I use a tape emulator because of characters dropping. I had Okuma application specialists and our Cimco rep trying all kinds of things to get it to transfer without losing characters.
    The Cimco DNC guy recommended this... ADR BTR forOkuma OSP5000with Sanyo 2302 Tape Reader
    Little expensive but works great.

    My Okumas with 5000L-G or newer control does not need the emulator...just the 5000L and older machines.
    ok yeah.. alittle expensive you say.. i say alot :p

    yeah that might be my only solition - i dont have the money for that hardware lol so i will have to get around with it untill i want to throw that kind of money after a machine that i gave about the same for. lol

  8. #8
    Join Date
    Feb 2018
    Country
    DENMARK
    Posts
    54
    Post Thanks / Like
    Likes (Given)
    2
    Likes (Received)
    62

    Default

    Quote Originally Posted by Mtndew View Post
    2 things to look at.
    Is the baud rate the same?
    Have you tried getting rid of all spaces?
    Removing the spaces dosent change anything sadly..