Sequence Restart Sub programs
Close
Login to Your Account
Results 1 to 9 of 9
  1. #1
    Join Date
    Jan 2011
    Location
    telford, pa
    Posts
    356
    Post Thanks / Like
    Likes (Given)
    31
    Likes (Received)
    102

    Default Sequence Restart Sub programs

    Hello all new and old PM members! My question is for all the OSP experts out there. Can you do a sequence restart on a specific part within a sub program(routine?)? Its parting off multiple parts off of one slug of material, and using the Q with the sub programs. Is this possible?

  2. #2
    Join Date
    Sep 2018
    Country
    UNITED STATES
    State/Province
    Michigan
    Posts
    2
    Post Thanks / Like
    Likes (Given)
    0
    Likes (Received)
    0

    Default

    Possibly if you use a "GOTO" line # statement. With the OSP 7000 controller if using a variable it is easy

  3. #3
    Join Date
    Jun 2017
    Country
    NETHERLANDS
    Posts
    35
    Post Thanks / Like
    Likes (Given)
    0
    Likes (Received)
    1

    Default

    I don't understand what the problem is.

  4. #4
    Join Date
    Sep 2015
    Country
    UNITED STATES
    State/Province
    Ohio
    Posts
    782
    Post Thanks / Like
    Likes (Given)
    442
    Likes (Received)
    767

    Default

    I'm not sure what you're asking, but I don't see why not.
    Put N999 at the line you want to start at and then: restart. N999. sequence restart. cycle start.

    If you're jumping to that sub multiple times it's most likely going to restart at the first occurrence of that N though.

  5. #5
    Join Date
    Jan 2011
    Location
    telford, pa
    Posts
    356
    Post Thanks / Like
    Likes (Given)
    31
    Likes (Received)
    102

    Default

    thank you Booze, thats what i thought, with the sub being called with a Q, I guess the control cannot find anything but the first one.

  6. #6
    Join Date
    Sep 2015
    Country
    UNITED STATES
    State/Province
    Ohio
    Posts
    782
    Post Thanks / Like
    Likes (Given)
    442
    Likes (Received)
    767

    Default

    There is another way to restart but I didn't want to clutter up my previous post.

    In the upper right of the display there is a number that changes as the program is executed. It's the number of data blocks processed. If you run thru your program and note that number in the spot you want to restart at, it will restart there regardless of the number of times you jump to that sub.

    restart. 432 (for example). sequence restart. cycle start.
    432 being the data block you want to restart at. Caution, it will position at the last XZ in memory before the restarted data block number (and I think it does so in rapid).

    The only time I have ever restarted that way was in the middle of hogging a lot of stock with a LAP cycle and my insert failed. (Think 8" stock that turns into a 1" post with 8" flange.)

    Hope this helps.

  7. #7
    Join Date
    Jan 2011
    Location
    telford, pa
    Posts
    356
    Post Thanks / Like
    Likes (Given)
    31
    Likes (Received)
    102

    Default

    now i know you know your stuff! thanks Booze, we were doing that, sort of hairy but definitely works. hey, we encountered another issue with the same thing. we have a new LB (ex) and the code M91 for the stupid safety door kind of hangs up the restart. we get no alarms, it just opens the door and then your stuck. can't open the door or get it to continue. ever deal with the M90/m91?

  8. #8
    Join Date
    Sep 2015
    Country
    UNITED STATES
    State/Province
    Ohio
    Posts
    782
    Post Thanks / Like
    Likes (Given)
    442
    Likes (Received)
    767

    Default

    Sorry, I don't have that on my lathe.
    2000 ES-L8 w/ OSP U10L

  9. #9
    Join Date
    Sep 2018
    Country
    NIGER
    Posts
    3
    Post Thanks / Like
    Likes (Given)
    0
    Likes (Received)
    0

    Default

    hi james siffel , that thing described by Booze Daily is the internal sequence counter : it is there as a last resort, thus if you can't restart a program by using it then it means that something is wrong

    this counter does not reset in case of pushing the emergency-stop or the hard-reset-button, helping to pin-point the last executed sequence

    it's value does not always represent the number of blocks, thus a program with 10 blocks may require more than 10 internal sequences to be processed by the controller ( think of cycles, looped codes, etc )

    it may behave faulty if it is used on a program that contains VRSTT, or if it is looped based on a common variable, thus based on a sequence that is executed from a source <> main program; try to restart a dnc like that




    for your program i would recomand restarting on the 1st block inside the soubroutine + order number <> 1 ( 2 for 2nd part, 3 for 3rd, etc ); this method is simpler

    kindly

    ps : i can't help with M90