Search Results - Practical Machinist - Largest Manufacturing Technology Forum on the Web
Close
Login to Your Account

Search:

Type: Posts; User: dana gear

Page 1 of 8 1 2 3 4

Search: Search took 0.00 seconds.

  1. Maybe it's me but I don't see a lot of them for...

    Maybe it's me but I don't see a lot of them for the 2H, I have one for the 2K that I have had for years.
    I don't know if you have tried the equipment wanted section, but I have had fair results in...
  2. Replies
    19
    Views
    814

    Wow, I sure would build some type of scatter...

    Wow, I sure would build some type of scatter shield for this thing, even small components at that RPM will launch a long way.
  3. To some degree it's the way it is. Our old...

    To some degree it's the way it is.
    Our old service trucks 1960 through 1970 and even into the 80's were all gas engines that just about any high school auto shop student could work on, dirt simple...
  4. Leave your current 200 amp panel for your 3 phase...

    Leave your current 200 amp panel for your 3 phase equipment, install safety covers to the unused spots.
    looks like a 3 phase Delta feed.
    Add a 100 amp 2 pole braker to the existing panel pulling...
  5. There are a bunch of serial number changes...

    There are a bunch of serial number changes through the LN-7 feeder series.
    You can check out the sequence of operation for your serial number LN-7 on Lincoln's web site under operators manuals....
  6. Replies
    10
    Views
    767

    The older Miller resistance spot welder...

    The older Miller resistance spot welder transformers were pretty much in destructible. That said there is the exception.
    Before you toss it I would check some of the basics, if you understand the...
  7. Replies
    2
    Views
    269

    are you missing the pin retaining block that...

    are you missing the pin retaining block that slides up and down to direct index or just the locking pin assembly ?
  8. You need to have a long talk to our California...

    You need to have a long talk to our California High way patrol Commercial inspector.
    In California travel/camp trailers need brakes on 2 wheels if the trailer weight exceeds 1500 lb, all trailers...
  9. One would think it did not matter, but I have...

    One would think it did not matter, but I have seen that same offset cut on other clamp systems before and they always favor the pull side.(side with the threaded pull-collier/nut, etc) Note on the...
  10. If your seeing a Torch cap fault yellow led...

    If your seeing a Torch cap fault yellow led during a cutting cycle first check that the Shield deflector/retaining cap or similar if using Fine cut consumables is installed correctly, You only want...
  11. Replies
    11
    Views
    782

    Keep in mind that the I/R 5 h.p. is not a 100...

    Keep in mind that the I/R 5 h.p. is not a 100 percent duty cycle compressor, meaning "Continuous operation".
    Trying to get a higher C.F.M and lower pressure continuously will require The compressor...
  12. Replies
    1
    Views
    353

    Give Air/Hydraulics a call 1-800-837-4355. They...

    Give Air/Hydraulics a call 1-800-837-4355. They should be able to hook you up with the information you need.
  13. Replies
    2
    Views
    477

    The Hypertherm Soft start inrush kit will help to...

    The Hypertherm Soft start inrush kit will help to some degree.
    The kit will decrease the effects of inrush current that occurs when the main contactor closes.
    Question, do you need the HPR 400 for...
  14. Replies
    10
    Views
    1,308

    My 2 cents worth, leave well enough alone, stay...

    My 2 cents worth, leave well enough alone, stay with the factory oil strainer. Most early American press brakes used only a serviceable strainer built into the hydraulic oil tank, or a canister unit....
  15. Hypertherm, hands down

    Hypertherm, hands down
  16. Yup, most of the punch presses I encounter here...

    Yup, most of the punch presses I encounter here on the northern parts of these United states are just plain worn out.
    I saw one a couple weeks ago, the bull gears were so bad that when it came over...
  17. When the units were shipped new with the almost...

    When the units were shipped new with the almost vertical down type intake filters the compressor was meant to be installed inside some type of weather proof structure/indoors. In fact (and I will...
  18. Replies
    13
    Views
    817

    The unit appears to be a 120 A.C. volt power...

    The unit appears to be a 120 A.C. volt power unit, if that is the case then it most likely is a lower volume pump unit( gallons per minute)
    It probably will push up to 2500 psi, just be careful when...
  19. Replies
    6
    Views
    530

    It was made for a shaper or mill. The casting in...

    It was made for a shaper or mill. The casting in your picture list's the Schiller manufacturing plant that was from 1956 on prior to that they were at another location. the vise could be either...
  20. The 5120 could be configured with the air inlet...

    The 5120 could be configured with the air inlet filters pointing almost upside down from the factory.
    Typically you don't see a lot of oil blown back into the filters when there is a bad breather...
  21. You have it switched into the low volt setting...

    You have it switched into the low volt setting and wired correctly then when powered up (turned on) check for correct voltage between legs T-1 and T-2, also check between legs T-3 and T-4. be sure...
  22. Replies
    3
    Views
    707

    This just begs the question, what's wrong with...

    This just begs the question, what's wrong with using a hand drill?
    I know it's just wood but wait till his L-head, 10,000 rpm drill get's a bind into something...
    Brazil, hopefully they have a 911...
  23. Replies
    10
    Views
    971

    Some times if the bore will allow it seals work...

    Some times if the bore will allow it seals work great as the O.D. of the shaft is generally in good condition.
    With all the different size seals available there's generally one that will work.
    We...
  24. Try Schnitzer steel in Oakland 510-444-3919....

    Try Schnitzer steel in Oakland 510-444-3919. there always fair on scrap, and they have a bunch of locations.
  25. Replies
    16
    Views
    6,194

    Yup, very light duty with goofy overhead cabling...

    Yup, very light duty with goofy overhead cabling system.
    Early owners were left in the dust then the factory stopped software support and won't even provide support over the phone for there early...
Results 1 to 25 of 188
Page 1 of 8 1 2 3 4