  1. Replies
    11
    Views
    1,385

    An easier alternative may be to switch the motor...

    An easier alternative may be to switch the motor to something that is the next size down. The Victor 1640 seems to come with either a 5 Hp or 7.5 Hp motor, I doubt the latter would be able to start...
  2. Replies
    11
    Views
    1,385

    Overall a very poor design strategy to hard wire...

    Overall a very poor design strategy to hard wire the VFD inputs to the spindle control as you have outlined, there are no safety interlocks or resets through the stop position. The foot brake switch...
  3. Replies
    11
    Views
    1,385

    If it is a constant Hp motor, than just run it on...

    If it is a constant Hp motor, than just run it on the 8P setting and run it to 120Hz. If the motor is not constant Hp then run it on the winding that gives you the highest Hp and use the VFD to...