  1. There are 3 sensors visible from outside, one in...

    There are 3 sensors visible from outside, one in water (lower part of chiller), the second one ambient air sensor in chiller (top, visible in mesh near display) and the external one which is attached...
  2. Hi, you need sensor which is in cooler unit? Ask...

    Hi, you need sensor which is in cooler unit?
    Ask Mike from jestertechnologies
  3. Yes, there are 2 pairs of white and black wires,...

    Yes, there are 2 pairs of white and black wires, one to limit switch and the other ones to mesh.
    Look at photos in attachment 269930

    Limit switch is to verify if the wire chopper is in place.
  4. Hi, these two wires are to detect wire problem,...

    Hi,
    these two wires are to detect wire problem, they are connected to mesh above and below wire path near roller.
    To detect wire you should have blue wire that connect to plate and the plate...
  5. Mitsubishi serviceman checked flushing and it's...

    Mitsubishi serviceman checked flushing and it's good. During test cuts the nozzle gap were 0.2mm. I have the same machine and we can compare behaviour between these two machines, flushing is nearly...
  6. Mitsubishi FX20 - wire breaking problem, slow machining

    Hi
    my friend have problem with FX20, the machining is very slow, unstable and wire breaking occurs frequently so the machine is unusable.

    We did some tests.

    1. Material height about 30-40mm -...
  7. Replies
    6
    Views
    1,038

    I had the same problem, check all connections -...

    I had the same problem, check all connections - boards on right side of electrical cabinet - SIFA and KOSC - i suggest to get out SIFA board with all connectors and reinstall them. Try reseat and...
  8. I checked everything twice and the addresses are...

    I checked everything twice and the addresses are good but not all.
    As you see on photo
    A90000 looks ok, but next row which first bit (bit F) is upper head float state is 0 238253

    i enclose ...
  9. Mitsubishi FX20 - problem after relocation, upper head float alarm

    Hello all

    we bought mits fx20 1997, in seller's garage the machine was working. After relocation and installing machine we have problem with alarm "U730 T/C in wasser 0000" which inform that upper...