  1. The evaporator has a multicircuit feed. If you...

    The evaporator has a multicircuit feed. If you looked it has a capillary tube feeding each of the circuits. Most likely wax from the oil has plugged off one of the tubes. The typical fix for that is...
  2. I don't know why it's running reverse. But I've...

    I don't know why it's running reverse.
    But I've had two window units that stopped working, and I replaced with a new unit. I went to scrap the old units, and found both had extreme dirt on the...
  3. Replies
    25
    Views
    1,179

    If there is a power factor capacitor bank that...

    If there is a power factor capacitor bank that you can purchase for your Dynasty 300, that will make a difference in peak amperage used during welding.
    I have a single phase Synchrowave 250, that is...
  4. Replies
    24
    Views
    1,482

    Harris 150L20C 150V 6500A 1600pF Metal Oxide...

    Harris 150L20C 150V 6500A 1600pF Metal Oxide Varistor - NEW MOV | eBay

    or the search
    https://www.ebay.com/sch/i.html?_from=R40&_trksid=p2553889.m570.l1313&_nkw=varistor+150v+20a&_sacat=0
  5. Replies
    24
    Views
    1,482

    These varistors should have been wired to ground....

    These varistors should have been wired to ground. Get two news ones, of the same value, and wire them to ground not differentially across the 240 power. If they are for surge arresting you want the...
  6. Replies
    47
    Views
    3,621

    I can't help with the move. The lathe belt, use...

    I can't help with the move. The lathe belt, use one of those link belt types that enable you to thread it back around the spindle V pulley and motor. That way you won't have to remove the spindle...
  7. Thread: My new Monoset

    by ignator
    Replies
    39
    Views
    3,767

    The second photo, as sketched, is showing sine...

    The second photo, as sketched, is showing sine (opp/hyp), not tangent (opp/adj), slight different arcsine angle is 9.449 degrees. Probably don't matter for this oil groove application.
    I thought I...
  8. Replies
    30
    Views
    3,300

    Back when dialup was the connection, McMaster...

    Back when dialup was the connection, McMaster Carr would load fast. Even as you typed in the search window, quick flow down selections would be displayed.
    MSC was into java script, and animation to...
  9. I'm just guessing here but experience in closed...

    I'm just guessing here but experience in closed loop systems say's either your shaft encoder has a problem, but this may be as simple as a loose set screw, or the optical grating has come loose from...
  10. I have a HECO spotting scope. Here's a jpg of the...

    I have a HECO spotting scope. Here's a jpg of the instructions;
    321971

    The yellow sheet is an addendum indicating only the horizontal line of the graticule is to be used.
  11. Here you go; Feeder and Secondary Tap Rules...

    Here you go;
    Feeder and Secondary Tap Rules

    If you read the text, It is for distributing the secondary of a transformer from the power company source. Or feeders sourced from a main panel to...
  12. What is that rule? All I know is the ampacity of...

    What is that rule? All I know is the ampacity of the wire must stay to the size required to trip a breaker, so no 12AWG taps on 6AWG wire without a fuse stuck inline (and I'm not sure that's code,...
  13. I'm north of Cedar Rapids 8 miles, I'd help you...

    I'm north of Cedar Rapids 8 miles, I'd help you out if I was closer. My sister lived in West Des Moines, just north of the Ballroom, back in 1992.
  14. You can parallel many of the 20amp 240volt...

    You can parallel many of the 20amp 240volt outlets off one breaker. Looks like that panel has no spare connections available for another 20amp 240V dual pole breaker. I would find the lowest cost...
  15. That's a bad idea. You want a subpanel, Menards...

    That's a bad idea. You want a subpanel,
    Menards have them, should be one close to you:...
  16. Is this 50amp circuit connected to wall outlets?...

    Is this 50amp circuit connected to wall outlets? Or is this just a power feed from a main breaker to the shop and connected to nothing right now?
    Anything connected to this requires 6AWG copper to...
  17. Replies
    13
    Views
    950

    I was looking for the circuit card schematic, for...

    I was looking for the circuit card schematic, for the velocity control. I assume it's a half wave SCR circuit. And yes I could spend the time to remove the card, and reverse engineer it, but I...
  18. Replies
    13
    Views
    950

    Jon, do you have a schematic for this power feed?...

    Jon, do you have a schematic for this power feed? Can you share it?
    I installed this years ago, and the manual never had a schematic.
  19. Replies
    13
    Views
    950

    I'll check that. Thanks Jon

    I'll check that. Thanks Jon
  20. Replies
    13
    Views
    950

    No issues with motor, just this runaway problem...

    No issues with motor, just this runaway problem from time to time.
    Servo 150;
    319928
  21. Replies
    13
    Views
    950

    I know your cost in Australia will be more with...

    I know your cost in Australia will be more with VAT and exchange rate. The phase control circuit of the SCR/TRIAC is just too simple, and I've tried to see about making the potentiometer have a...
  22. Replies
    13
    Views
    950

    I started with a USA brand, Servo, for my...

    I started with a USA brand, Servo, for my Wells-Index mill many years ago, sold by Enco. I think I paid $600 USD. They had the custom mount that fit my mill. I've had problems with it shortly after...
  23. Replies
    13
    Views
    910

    As JST commented, search for "carrier frequency"...

    As JST commented, search for "carrier frequency" in your VFD manual, this is changeable.
    One of my VFDs is settable from 750Hz to 16KHz. The issue is if you use a very long wire from the VFD to the...
  24. Replies
    180
    Views
    9,924

    Ya, I can imagine trying to get this mounted back...

    Ya, I can imagine trying to get this mounted back in a machine, and trying to get that ring (that just fell into a black hole, where you can't see where it rolled) on, and then to try to get the hose...
  25. Replies
    180
    Views
    9,924

    It's in their patent. US4858470A - Vibration...

    It's in their patent.
    US4858470A - Vibration transducer mounting
    - Google Patents

    There's an inner ring under the hose clamp. The patent shows a ratchet pawl type finger hose clamp. But...
Results 1 to 25 of 431