  1. So when paralleling two idlers is rotation the...

    So when paralleling two idlers is rotation the only thing that you have to worry about? Ie: both idlers rotating same way?
  2. Replies
    3
    Views
    481

    Three phase 200 volt motor

    Why does Baldor (USA) make a 200 volt motor. Should one be wary of running this motor on 245 volts?
  3. Replies
    4
    Views
    583

    I was concerned with the y primary with the...

    I was concerned with the y primary with the centre grounded. I was talking to a guy who said when he wired his Phase Converter to a y delta transformer, there was a substantial current to Ground. He...
  4. Replies
    4
    Views
    583

    Transforming converter voltage

    Converting 3 phase voltage from 230 to 600 on a y -delta transformer should one be concerned about the high reference to ground in the generated phase. Should you disconnect the reference to ground...
  5. Replies
    1
    Views
    498

    H258651ere is 258651258651 Here is another...

    H258651ere is 258651258651
    Here is another picture
  6. Replies
    1
    Views
    498

    Self assembled rotary Phase Converter

    I have been building rotary Phase Converter’s for a number of years. Here is a recent build using a TD relay to drop out the start capacitance and energize a contactor for an remote load. 258650
  7. Replies
    5
    Views
    637

    I258648258648258648

    I258648258648258648
  8. Replies
    5
    Views
    637

    Self assembled

    Here is one of my self assembled models
  9. Replies
    180
    Views
    371,211

    Sticky: 258588 Self assembled model

    258588
    Self assembled model
  10. Yes I thought a screw compressor would be an...

    Yes I thought a screw compressor would be an easier start.
  11. Thanks for the good responses. It is my...

    Thanks for the good responses. It is my understanding that a split phase motor has more starting torque than a three Phase motor. In this case if the screw had a three phase motor, the starting...
  12. Excessive amp draw on screw compressor upon start

    Friend ordered a screw compressor with a single phase 7.5 hp motor. When he starts it it dims the lights to his whole acreage. He is 60 ft from the pole so voltage drop is not an issue. What could he...
  13. Replies
    10
    Views
    1,026

    Sounds great. I will do that. Thanks much.

    Sounds great. I will do that. Thanks much.
  14. Replies
    10
    Views
    1,026

    RustySparks. I think you have diagnosed the...

    RustySparks. I think you have diagnosed the problem accurately. The only relay I was able to find was labeled “universal” but obviously does not work for me. What do you think about using a timer to...
  15. Replies
    10
    Views
    1,026

    I checked the wiring and tried to start the...

    I checked the wiring and tried to start the converter again. It started and then growled ferociously. I quickly pulled off the wire from the coil of the starting relay. The converter settled down and...
  16. Replies
    10
    Views
    1,026

    Your reply to my problem encourages me to not...

    Your reply to my problem encourages me to not give up on on this venture. I have been wiring my converters so that the relay that brings in the start capacitor stays energized as long I have the...
  17. Replies
    10
    Views
    1,026

    All of the potential relays I have seen have seen...

    All of the potential relays I have seen have seen are for single phase hard start applications have normally closed contacts. The emf generated by the start winding fires the relay associated with...
  18. Replies
    10
    Views
    1,026

    Potential relay wiring.

    I am trying to wire a potential relay into my rotary Phase Converter for remote starting. I am not having success. Here is the wiring diagram that I found on the web. Any ideas. 256254
  19. Replies
    7
    Views
    1,190

    Special fitting

    I need a fitting to connect a temperature gauge to the thermostat housing on my motor. The outlet is 3/8 npt. The brass fitting that comes with the new gauge is marked 1/2 - 14 NPT. I thought this...
  20. Replies
    180
    Views
    371,211

    Sticky: Here are pics of a few I have made. The vertical...

    Here are pics of a few I have made. The vertical mount motor is on a brake drum. lol
    204186
    204187204186204188204189204190
  21. Replies
    180
    Views
    371,211

    Sticky: 204178204179204180204181204182

    204178204179204180204181204182
  22. Replies
    11
    Views
    3,121

    I have been assembling rotary phase converters...

    I have been assembling rotary phase converters for many years as well as servicing and taking in on trade many different commercially made models. I have found that the commercially manufactured...
  23. Replies
    4
    Views
    1,434

    Potential relay problems could be eliminated with...

    Potential relay problems could be eliminated with a manual push button activation of the start caps.
  24. Replies
    11
    Views
    3,121

    Thank you all for your responses. Your knowledge...

    Thank you all for your responses. Your knowledge amazes me. I sent e-mails to three large converter manufactures and was supersized to have engineers phone me back. They lost me pretty quick with a...
  25. Replies
    11
    Views
    3,121

    Phase converter and transformers

    Hello !! First post but have been lurking around for awhile. My question is hooking up a three phase step up transformer to a rotary phase converter. 230 1 ph to 600 3 ph. I have assembled many...