  1. Replies
    3
    Views
    192

    Show ALL the wires..... for reversible, there...

    Show ALL the wires..... for reversible, there are usually 5 wires into the motor. Sometimes 4. If not 5 wires, then that switch is likely the wrong one.
  2. Replies
    51
    Views
    2,884

    Eating is a sure precursor to death. Sometimes...

    Eating is a sure precursor to death. Sometimes very quick, other times slower.

    Breathing, ditto

    drinking water ditto.

    Quitting is not advised by the better medical experts, however.
    ...
  3. Replies
    17
    Views
    1,003

    None that I have seen have any stops. For that...

    None that I have seen have any stops.

    For that matter, I don;t know that I have ever seen it on a wood box. Pull out, set on bench, get what yu want, put back. not the brightest way, but at...
  4. Replies
    15
    Views
    845

    If your switch has an appropriate HP rating, then...

    If your switch has an appropriate HP rating, then you are fine.

    Otherwise, maybe not..... the HP rated switches have large short term overload capability, the current rating is not what you use, ...
  5. Replies
    18
    Views
    1,489

    That's a possibility. OP has not been back...

    That's a possibility.

    OP has not been back in a month..... either he solved it, gave up, decided we were no help, or it electrocuted him. Dunno which, hope not the latter.
  6. Replies
    10
    Views
    809

    You don't have much friction area. I'd be...

    You don't have much friction area. I'd be tempted to put in some blocks against that "spigot" to help hold it, or flip it and set it on a larger ring.

    But, all it has to do is work for a couple...
  7. Replies
    10
    Views
    809

    If the rotab has a smooth ground surface, then...

    If the rotab has a smooth ground surface, then either lay down a sheet of thin paper first, or rough up the surface a bit. Either will give more "grip" for a given force down. With the stud and...
  8. Replies
    34
    Views
    1,753

    Good idea from the safety point of view.. ...

    Good idea from the safety point of view..

    Problem is, "V^2" goes up a lot faster than "m". The payoff for more speed is just way better, especially if weight is a consideration, and it usually...
  9. Replies
    10
    Views
    809

    Or get the t-slot nut right up to the part, so a...

    Or get the t-slot nut right up to the part, so a lot of the force is just compression on the slot material.
  10. Many still have an inductor.... but it is before...

    Many still have an inductor.... but it is before the DC link cap, so spikes are absorbed.
  11. Replies
    49
    Views
    2,077

    Yah think? No difference except voltage..... ...

    Yah think?

    No difference except voltage.....

    EU has 230V and neutral. US has 120V and neutral. Same system, different voltage, derived from 3 phase instead of center tapped single phase. ...
  12. I cannot think of ONE reason why running the VFD...

    I cannot think of ONE reason why running the VFD with nothing connected could be an issue. I have done this a lot, when debugging new designs, and it just is not a genuine problem for any modern...
  13. Replies
    49
    Views
    2,077

    The "sat for xx years unused" (where there are...

    The "sat for xx years unused" (where there are mice etc) could not have anything to do with it, of course.........
  14. Replies
    51
    Views
    2,884

    The link originally was thought to be aluminum...

    The link originally was thought to be aluminum cookware. And it is bad to cook acidic stuff in aluminum, but not due to Alzheimer's.

    As far as I know, just about all of it has been debunked. ...
  15. Replies
    49
    Views
    2,077

    OK, then in that case the reversal theory falls a...

    OK, then in that case the reversal theory falls a bit short. It was sounding like there was another issue, but that was probably a misinterpretation of what was said, or conflating what YOU said...
  16. Replies
    49
    Views
    2,077

    It's a little surprising that the GFCI trips...

    It's a little surprising that the GFCI trips before the breaker, but they are intended to trip fast, so it is possible. Dead shorts usually trip a breaker pretty fast also.

    Yes, that sort of...
  17. Replies
    36
    Views
    2,125

    Okee.... Your post has it at .005". I suspected...

    Okee.... Your post has it at .005". I suspected you wanted another zero.

    You could always stick a better vial in the 98..... that has been done before...... Saves a fair bit of fab if you can...
  18. Replies
    49
    Views
    2,077

    Not SUPPOSED TO care. Depends what is...

    Not SUPPOSED TO care.

    Depends what is connected where. There may be things connected hot to neutral and neutral to ground, like capacitors. The would not cause an issue if correctly polarized,...
  19. Yep, that is a good way, and it ends up looking...

    Yep, that is a good way, and it ends up looking for other faults as well, like failed capacitors, etc, etc. It does evade the usual "bridge two power terminals" solution, which will not help.
    ...
  20. Replies
    36
    Views
    2,125

    If that is the true number you want, a Starrett...

    If that is the true number you want, a Starrett 98 would do you. 0.005"/12", and considerably smaller width in the 6" size..

    It does have a semi-circle recess in the bottom, but it takes up only...
  21. Replies
    24
    Views
    1,219

    Out of that 2K bucks, save enough for SOME kind...

    Out of that 2K bucks, save enough for SOME kind of generator.

    There will be times when you need to recharge. Assuming you are running lead-acid batteries now, as most do, you will NOT want...
  22. Replies
    5
    Views
    528

    Pretty common to do that for small loads on a...

    Pretty common to do that for small loads on a machine.

    ALL power is tapped off 3 phase, so, yes. If you have several such separate loads, it is best to use different wire pairs (phases) for...
  23. Replies
    25
    Views
    1,592

    Even of you DID have parts missing? Hmmmmm.........

    Even of you DID have parts missing? Hmmmmm......

    Yes. it has been done to control just two of the three legs. Used to be common. and it is not so horribly unsafe, there are disconnects to fix...
  24. Replies
    20
    Views
    1,094

    OK, I have done a bit of this before. 2...

    OK, I have done a bit of this before.

    2 issues...

    first is direct noise from a machine.

    second is noise reflected from walls

    For the first, you put absorbing material between the machine...
  25. Replies
    24
    Views
    1,219

    He's down the coast, look it up. In the "thin...

    He's down the coast, look it up. In the "thin part" along Canada.

    That's still up at Hudson Bay type latitude, but well below the circle. Like I said, think North Scotland, Orkneys maybe.

    On...