Search Results - Practical Machinist - Largest Manufacturing Technology Forum on the Web
Close
Login to Your Account

Search:

Type: Posts; User: SeymourDumore

Page 1 of 60 1 2 3 4

Search: Search took 0.05 seconds.

  1. You Are Welcome! Actually, the real intention...

    You Are Welcome!

    Actually, the real intention was a Redneck Genius, but whotever.

    Y'now!
    Cars perched on ol' tires 'll keep'm dry and rust-free(er).
    Sealed Bud cans 'll keep shit afloat when...
  2. Sumbitch wmpy !!! You're a freakin' genius!!! ...

    Sumbitch wmpy !!!
    You're a freakin' genius!!!

    Never mind chunks of wood, rather larger pieces of sponges!
    No banging, no splashing.

    ( Damm, someof'm rednecks truly deserve a real prize! )
  3. Like Nerdlinger said, large bin with water. The...

    Like Nerdlinger said, large bin with water.
    The water actually has a couple benefits.
    First, draining off the coolant is almost pointless as there is precious little to save.
    BUT!!! the water bath...
  4. Replies
    2
    Views
    247

    IF!!! your control supports it, you can write a...

    IF!!! your control supports it, you can write a G83 cycle using I J K instead of Q.

    I : First peck depth
    J: Amount to reduce successive peck depths
    K: Minimum peck depth

    So, let's say you...
  5. Dumb thinkin' here ... Would it be possible to...

    Dumb thinkin' here ...

    Would it be possible to invert the post count of the member in question, which could then be used to trigger the "Granite" status?
    IOW if the post count is negative, then...
  6. Replies
    13
    Views
    619

    Well, may want to forget about the serial stuff (...

    Well, may want to forget about the serial stuff ( RS232 ) and just roll with the PCMCIA instead.

    Them Japs have never really figured out the idea behind a serial comms, and as a result all of...
  7. Dunno about what should go where. Isolate or...

    Dunno about what should go where. Isolate or transfer vibration, but these guys are in that business:


    Vibration isolation pads - AirLoc - for machine installation
  8. Replies
    16
    Views
    1,023

    What-if : instead of a dimensional Go/No-go...

    What-if : instead of a dimensional Go/No-go inspection, change to a functional pass/fail check?
  9. Replies
    37
    Views
    3,370

    With G98 P1234 call, there must be a registered,...

    With G98 P1234 call, there must be a registered, separate program in the control.
    With a G98 Q1234, there must be a block# N1234 in the SAME program.

    IOW, a G98 P call is a subPROGRAM call,...
  10. Replies
    37
    Views
    3,370

    While all that is correct, I think the OP's...

    While all that is correct, I think the OP's question was more along the line of how does one approach multiple part programming.
    Yes, the discussion has taken a turn towards what their CAM can or...
  11. What is the name of the file on your PC? The...

    What is the name of the file on your PC?
    The Haas accepts the same file name as it is on the PC side without regard of the actual contents.
    IOW the NextGen control does not interrogate the...
  12. Replies
    1,147
    Views
    91,711

    Rob, Just please... Fuck-Off! We already have...

    Rob, Just please... Fuck-Off!
    We already have Rozen and Triumph(something) championing for the spot, and they are way ahead of you.
  13. I am assuming ( Gordon-like) that you are...

    I am assuming ( Gordon-like) that you are referring to cutter comp ....



    I have to ask why you would do this ? [/QUOTE]

    Because threadmilling with comp lets you get to the finish line...
  14. Replies
    28
    Views
    2,005

    OK, so WTF did I miss ... And I mean, JWTF did I...

    OK, so WTF did I miss ...
    And I mean, JWTF did I miss in 10 minutes after the OP?
    Turkey and Canada defending Who and What exactly?
    Against Who and What exactly?
  15. Replies
    22
    Views
    1,740

    I've got like 30 or so of these from the 11" high...

    I've got like 30 or so of these from the 11" high ones.
    Same fiberglass with molded-in wire mesh.
    I can assure you, they hold #500 ea. while stacked 3 high!

    Plexton Stack and Nest Containers
  16. That is a builder-specific issue and not Fanuc....

    That is a builder-specific issue and not Fanuc.
    My Haas SL10 and the Mori Duraturn with the Fanuc Oi works fine with a manual ( not MDI ) turret index and correctly picking up the work offset.

    On...
  17. Replies
    10
    Views
    952

    Seriously? What exactly in a transformer needs...

    Seriously?
    What exactly in a transformer needs a daily workout?
    The AL or CU winding?
    The Iron or laminated core?
    Or perhaps the flux?
  18. Replies
    3
    Views
    736

    I have it set up so the through hole is blocked...

    I have it set up so the through hole is blocked on the back side. It is then a blind hole so it "should" be flushing properly.

    Nope, incorrect thinking! While you may have the flushing, the...
  19. Replies
    2
    Views
    509

    You may be a bit off on either the date of that...

    You may be a bit off on either the date of that machine OR the model!

    In 1997 Brother was still with the HS3100, HS3600 or HS5100 series.
    Then came the HS50A sometime in the late 99 or early 2000...
  20. Len First off: No E.T. Phone Home! The PC...

    Len

    First off: No E.T. Phone Home! The PC they use has access to the network, but not to the web.
    Second, it's my shop and they're my responsibility.
    I'll provide the tools necessary, let it...
  21. I absolutely WILL check that out! Thank You!!!

    I absolutely WILL check that out!
    Thank You!!!
  22. Can't help you on the Doosan implementations,...

    Can't help you on the Doosan implementations, but..

    Endmills are typically Direction 0 as mentioned earlier.
    I am guessing M35 is your C axis connect function.
    Did you try to put in G17 before...
  23. We'll find out on Jan 2 if the "free" version...

    We'll find out on Jan 2 if the "free" version still works.
    Based on the pop-up, it won't.

    My ACAD maintenance is with ADSK, it is up to date, but it has nothing to do with draftsight.

    I am...
  24. Alternatives to DraftSight ( or any DWG viewer with editing function )

    Guys, I have a problem.

    I use Inventor and ACAD for all my CAD work. Modeling is done in IV, then immediately a true AutoCAD DWG is created from everything.
    They are not dimensioned,...
  25. Sticky: Check the Automation forum.... And for the...

    Check the Automation forum....
    And for the record, that is Miguels244!
    ( get it right before some Dane slaps you in the head for it! )
Results 1 to 25 of 1500
Page 1 of 60 1 2 3 4