Search Results - Practical Machinist - Largest Manufacturing Technology Forum on the Web
Close
Login to Your Account

Search:

Type: Posts; User: Hoss710

Page 1 of 16 1 2 3 4

Search: Search took 0.01 seconds.

  1. Replies
    3
    Views
    231

    that is a new version of there old vr6 and vr11...

    that is a new version of there old vr6 and vr11 machines that were made around 2000 ish. I personally liked the machine, and it was fairly popular with the aerospace industry. its 1 drawback on the...
  2. Replies
    117
    Views
    7,563

    Haas direct phone number. 8052781800. that...

    Haas direct phone number. 8052781800. that should be a 4 to 6 position selector switch. being you don't have 5th and 6th axis a 4 position should work fine.
  3. Replies
    117
    Views
    7,563

    look at parameters 462 to 497 and see if anything...

    look at parameters 462 to 497 and see if anything looks odd. also If you don't have a original parameter list. call haas and they will email a list to compare it to what you have.
  4. Replies
    117
    Views
    7,563

    no that is controlled rs232. that's for the early...

    no that is controlled rs232. that's for the early 5c indexer options on the early vertical machines. they use the same control for both vertical and horizontal. if I get time this evening I'll see...
  5. Replies
    117
    Views
    7,563

    it should be the 20 to 1 as it should match the...

    it should be the 20 to 1 as it should match the gearbox. there should be a parameter that is marked t.c. disabled.if its 1 change it to a 0. does the machine have a vector drive? if it doesn't and...
  6. Replies
    117
    Views
    7,563

    Best bet is call Haas on that 1 to e certain. ...

    Best bet is call Haas on that 1 to e certain. most of the time they include a sheet explaining the differences with the board. I haven't forgotten you. it's just been Crazy on my end. way to many...
  7. Replies
    9
    Views
    435

    as last I heard on the next gen control. a haas...

    as last I heard on the next gen control. a haas tech uses a algorithm to unlock the parameters. the parameter for orientation changes once a encoder is removed. if you mark everything carefully it...
  8. BGL is correct!

    BGL is correct!
  9. Replies
    7
    Views
    321

    gotcha I didn't see that part ! then its either a...

    gotcha I didn't see that part ! then its either a bad diode in the matrix. or the keypad is shorted or broken. a very common issue of a machine of that vintage.
  10. for the most part any software above 10 version...

    for the most part any software above 10 version would do you no benefits. and without a parameter converter you would be doing yourself a great injustice. most of my later year calls when at haas...
  11. Replies
    7
    Views
    321

    what is your nitrogen pressure at ?

    what is your nitrogen pressure at ?
  12. Replies
    117
    Views
    7,563

    Agreed, encoder and rs232 would not burn...

    Agreed, encoder and rs232 would not burn anything up. what would burn a motor up driver up is if someone used a macro forced output and didn't cancel it. that would cause the motor to want to drive...
  13. Replies
    117
    Views
    7,563

    that is a possibility. I did find a list for the...

    that is a possibility. I did find a list for the Horizontal to be able to force outputs thru macro variables. and some factory bulletins. if you want copy of the information, send me a PM with ur...
  14. I worked for haas for 10 years. during that time...

    I worked for haas for 10 years. during that time I got to know the guys who built the 4th axis, the guys who did the gearboxs, the production manager, the people who assembled the machines. during...
  15. Replies
    9
    Views
    435

    if it were me , I'd mark the shaft and encoder...

    if it were me , I'd mark the shaft and encoder pulleys as fine and as close as possible. then remove the gear on the motor end, and replace the bearing. and put everything back together as marked.
  16. Replies
    9
    Views
    435

    it's a algorithm. so it factors in SN, clock...

    it's a algorithm. so it factors in SN, clock time , and a few other variables. unfortunately is a close guarded secret how its calculated.
  17. No the spindle cartridges are not the same. they...

    No the spindle cartridges are not the same. they may physically fit the housing. but the bearings are indeed different. you may be able to cheat the parameters. but you will have premature failure!
  18. Replies
    8
    Views
    536

    machine needs to be leveled to a nats ass with no...

    machine needs to be leveled to a nats ass with no pressure on the middle feet. then bring the middle feet down so they just touch the pucks and recheck level. also while leveling run your Y axis in...
  19. I just found the factory voltage check points of...

    I just found the factory voltage check points of the vector drive. along with a ton of other factory information I forgot I had lol. read your PM I sent you.
  20. You would have to visit Kaiser website to see if...

    You would have to visit Kaiser website to see if they make a smaller unit. but I see no issues running 2 phase converters and the sx6. if you want to be double sure. I would do this. ( i did this in...
  21. as long as neither mill is a Super Speed you...

    as long as neither mill is a Super Speed you should be ok. the screw compressor draws less current than the piston style pump.
  22. find a used Kaiser sx6. you will love it and it...

    find a used Kaiser sx6. you will love it and it will hardly work. it starts unloaded, it's a screw machine and way quieter than a piston unit. also add a few expansion tanks. I have 1 running a...
  23. I thing I forgot to mention, is that with the...

    I thing I forgot to mention, is that with the 340vdc not hooked up. after you are done with voltage checks. the unit should stay off at least 30 minutes as there is nothing to discharge the...
  24. Ok leaving the 340 vdc to the axis drivers off is...

    Ok leaving the 340 vdc to the axis drivers off is no problem. you can also leave the motor leads off of the spindle motor as long as there are no spindle commands, Including power up restart.you...
  25. Replies
    117
    Views
    7,563

    I don't own a hs1rp. I use to be a service guy...

    I don't own a hs1rp. I use to be a service guy for haas and we had a few in my territory back in the day. I'm not sure who would still have 1 as many had upgraded to the 400 and 500 units before I...
Results 1 to 25 of 380