Search Results - Practical Machinist - Largest Manufacturing Technology Forum on the Web
Close
Login to Your Account

Search:

Type: Posts; User: JST

Page 1 of 60 1 2 3 4

Search: Search took 0.18 seconds.

  1. Replies
    61
    Views
    2,183

    Steelman method is the same idea in reverse. ...

    Steelman method is the same idea in reverse.

    Instead of creating 2 phase via the 90 deg phase shift and then converting to 3 phase with the Scott connection, the motor is converted to a 2 phase...
  2. I have a porta-power setup that came with a shop...

    I have a porta-power setup that came with a shop made setup made like that that they actually used for some sort of testing. Had the tension rods etc. I guess it worked fine, all I wanted was the...
  3. Yes. True.

    Yes. True.
  4. Replies
    61
    Views
    2,183

    Whatever..... The OP has the thing, and it...

    Whatever.....

    The OP has the thing, and it does what it does at the full 15 HP. I don't know much about filling scuba tanks and admit it cheerfully.

    But I DO know that with a smaller pulley...
  5. Standard deal for HF and the like to use a bottle...

    Standard deal for HF and the like to use a bottle jack. I guess they work..... The way that one is I have not seen as often, but that one looks locally built. Usually the bottle jack is inside the...
  6. Replies
    61
    Views
    2,183

    Many ways to skin that octopus. If using the...

    Many ways to skin that octopus.

    If using the pulley trick, make sure the lube will still be OK. That size may be pumped lube, splash lube may not work as well at a slower speed.
  7. Replies
    49
    Views
    3,266

    There is an explanation of how to set that up. ...

    There is an explanation of how to set that up.

    Logan Lathe Back Gears
  8. Replies
    61
    Views
    2,183

    You don't even need to buy them with a particular...

    You don't even need to buy them with a particular power factor, synchronous motors can have the PF adjusted by changing the excitation, the current in the field coils.

    But that is a different...
  9. Replies
    10
    Views
    495

    Amps is what runs the motor. Voltage is just the...

    Amps is what runs the motor. Voltage is just the "push" behind the amps that causes the current to flow. So if the current in all three "legs" is equal, the motor should be well-balanced and...
  10. Replies
    61
    Views
    2,183

    50HP single phase irrigation pump motors can be a...

    50HP single phase irrigation pump motors can be a bit thin on the ground...... Baldor stocks up to 15 HP......

    I mean, YOU can GET them, but........

    Large Horsepower Single Phase Motors Up to...
  11. Replies
    49
    Views
    3,266

    yes, I "SAW" past the beginning of that, and...

    yes, I "SAW" past the beginning of that, and "DRILLED DOWN" to the part you refer to.

    That is not the sort of countershaft I have, I know about those. I have a legit 200, serial 12,xxx (Feb...
  12. Replies
    61
    Views
    2,183

    Ja, it is the long way around the barn, in some...

    Ja, it is the long way around the barn, in some ways. For a constant load pump motor a half mile from anywhere out in a field, it's a very decent solution, though.

    A BFH is not a solution to a...
  13. Replies
    49
    Views
    3,266

    That makes me very happy that my bench 200 has a...

    That makes me very happy that my bench 200 has a Southbend countershaft, probably from a 9" model C, all open and simple.

    I helped a relative clean up a regular 200 that had the fancy drive box....
  14. Replies
    61
    Views
    2,183

    The horsehockey ain't where you think it is........

    The horsehockey ain't where you think it is.....

    That 85% is perfectly possible. What you have is an effect of improving the power factor of the motor. Motors at full load can get to 0.6 to...
  15. Replies
    49
    Views
    3,266

    The clank is not unusual. Mine quiets down if...

    The clank is not unusual. Mine quiets down if loaded (during a cut).

    I have thought about messing with the pin system, but there are bigger fish to fry in the shop.
  16. Replies
    61
    Views
    2,183

    Quite reasonable considerations about flywheel. ...

    Quite reasonable considerations about flywheel. Similar to what I came up with.

    It's a balance......

    The generated leg is made by "generation" as the rotor, with its magnetic field, is...
  17. Replies
    6
    Views
    514

    Good eye. I thought it was the tan version of...

    Good eye. I thought it was the tan version of GPO, but it does look like wood. Not the best plan, although the moisture aspect is not that bad, the parts attached should all be insulated...
  18. Replies
    61
    Views
    2,183

    Here for your edjumification is some information....

    Here for your edjumification is some information. This type relies on the 90 degree phase shift mentioned above, but uses an autotransformer, which has been the traditional approach since the 1930s...
  19. Replies
    61
    Views
    2,183

    Actually, the ones I know about (might not be...

    Actually, the ones I know about (might not be THAT one), can produce, at one load point, a very nice balance.

    Two things...

    A capacitor can produce a phase shift of 90 deg.

    The shift in...
  20. Replies
    61
    Views
    2,183

    Not sure if you are a spammer or a legit...

    Not sure if you are a spammer or a legit poster.... likely a spammer, considering the insistence on a particular brand name, and post history.

    BUT......The transformer based type is perfectly...
  21. Replies
    6
    Views
    514

    Most likely the assumption is that code required...

    Most likely the assumption is that code required items of that nature will be external to the actual RPC. Those posting the diagrams do not provide "system diagrams". Phase-A-Matic USED TO provide...
  22. Replies
    6
    Views
    514

    Disconnect for RPC, yes. RPC ought to have a...

    Disconnect for RPC, yes.

    RPC ought to have a motor controller/starter yes. That is assuming the RPC wiring does not also run the load motors.

    The best method is to have the RPC only supply the...
  23. Replies
    18
    Views
    680

    Yes, it does take care of the HP. That can be...

    Yes, it does take care of the HP. That can be seen from the picture, although the Leviton spec page does not quote a HP rating. I assume, but do not know, that the picture is "actual" and not...
  24. Replies
    49
    Views
    3,266

    Probably the CS nut was made oversize so you can...

    Probably the CS nut was made oversize so you can fit it. The maker knows you have an old machine, and does NOT know what exact dimension you need.

    Mounting is just a flat surface with a hole in...
  25. Replies
    6
    Views
    418

    I know a guy in St Louis that has a 50 Hz...

    I know a guy in St Louis that has a 50 Hz electric-to-electric motor-generator type genset at about 7.5 kVA. At least he had it the last time I saw him, and he usually holds onto stuff.

    I...
Results 1 to 25 of 1500