Search Results - Practical Machinist - Largest Manufacturing Technology Forum on the Web
Close
Login to Your Account

Search:

Type: Posts; User: tomjelly

Page 1 of 29 1 2 3 4

Search: Search took 0.01 seconds.

  1. Replies
    152
    Views
    11,627

    I used to ride pretty much year round, even in...

    I used to ride pretty much year round, even in chicago if it was dry. These days with texting and distractions I don't think so. For a point and shoot bike these are looking better and better but...
  2. Replies
    30
    Views
    3,324

    I did rent one from home Depot once, same policy,...

    I did rent one from home Depot once, same policy, but it was Saturday evening before close and they said if I returned it Sunday they'd rent it without the scissor lift because it was so unlikely...
  3. Replies
    30
    Views
    3,324

    Anyone have one of Advance Metalworking'd...

    Anyone have one of Advance Metalworking'd Lo-riser trailers? Lo Riser Inclining Platform Trailers – Lo Riser and Lift-a-Load Trailers by Advance Metalworking
    I have a light lift a load from them...
  4. I downloaded a PDF of the owners manual, took a...

    I downloaded a PDF of the owners manual, took a screenshot of the operator panel with Sharex ( a fantastic windows screenshot tool) improved the resolution and cleaned up the image with Gimp image...
  5. Replies
    11
    Views
    623

    take apart the contactor if you can and check out...

    take apart the contactor if you can and check out the contacts. If they are pitted you may be able to dress them with a file to get by for a while, but you will probably need a new contactor.
  6. Jancollic good idea on the sign place & thanks...

    Jancollic good idea on the sign place & thanks Steve but this is not an actual capacitive touchscreen but a membrane cover.
  7. material for unavailable machine touchpad cover restoration?

    I need to replace a cracking and delaminated touch pad cover for a flat seamless plastic electronic control. There are metal, slightly raised "bubbles" underneath that actually are the contacts so...
  8. Thats exactly what I ended up doing, with a 60a...

    Thats exactly what I ended up doing, with a 60a fused disconnect on the supply side and a 30a breaker on the machine side. The tap burner runs fine in this configuration.
  9. Replies
    6
    Views
    357

    you missed the point. The first oil change will...

    you missed the point. The first oil change will essentially be a flush to be replaced with the OEM stuff if the machine works...
  10. I was shocked at how efficient those hvlp guns...

    I was shocked at how efficient those hvlp guns are when I first used one, much less overspray. I used half the paint for the same size job
  11. Replies
    6
    Views
    357

    Kaeser screw compressor oil

    I've ended up with a 2001 Kaeser SK19 screw compressor that was one of a pair from a small manufacturing facility, unknown history, sitting for about the last 6 years. They robbed a sensor off of...
  12. Referring back to the original post, this...

    Referring back to the original post, this transformer is going to be used solely for this single 460v load only, no need for any other output. in its original application there WAS a lead running...
  13. I know that the schematic shows to connect tap 5...

    I know that the schematic shows to connect tap 5 to 6 to get my intended voltage, but keeping in mind that I'm using this transformer as a step up rather than step down as originally intended, the...
  14. Before connecting that 5/6 jumper to ground, for...

    Before connecting that 5/6 jumper to ground, for the heck of it I put a voltmeter between that conductor and the ground coming from my supply and got 9.6v. Is this a problem as they will all be...
  15. Thanks, that makes sense to me. Just out of...

    Thanks, that makes sense to me. Just out of curiosity what amperage draw might I expect on my supply side when there is no secondary load on the transformer?
  16. Grounding of a single phase dry transformer used in reverse

    I have a 240x480 primary 120x240 secondary single phase transformer that I need to configure to run a 13amp 460v single phase electroarc tap burner on 240 service (to be used very infrequently,...
  17. I didn't put a tach on it, but I think so.

    I didn't put a tach on it, but I think so.
  18. 3 wires only. As it turns out, I tested it on...

    3 wires only. As it turns out, I tested it on 230 and it works fine, jumps right up to speed even with a 16" blade on it.
  19. this one is way oversize so I think it will be OK

    this one is way oversize so I think it will be OK
  20. igor, release the kites! I'm going with the...

    igor, release the kites!
    I'm going with the 1-0-2 configuration. I can't be sure the switches are break before make with the 0-1-2
  21. Dahlander motor rotary cam switch- off between speeds or not?

    I can get switches configured 1-0-2 or 0-1-2 to control my 2 speed single winding (dahlander?) motor, I see both types. Does the power need to be off to change between speeds or no? I was ready to...
  22. "If you take the first two numbers of a motor...

    "If you take the first two numbers of a motor frame, and divide that by 4, it provides the foot
    to shaft center line dimension."

    Thats handy to know, thanks! I'm going to take the table off and...
  23. Definitely not single phase.... 3 power leads...

    Definitely not single phase.... 3 power leads and ground, and he had a 3 pole contactor partially wired in there, but I'll be checking resistances prior to applying power anyway.. I also wonder...
  24. Well, its a beautiful, fully restored (except for...

    Well, its a beautiful, fully restored (except for the control) saw with the blade mounted directly on the specially made, long yet small diameter, and just rewound for the rebuild motor so a new one...
  25. how can I tell the design voltage of an unlabeled 3 phase motor?

    Just acquired a 16" Fay and Egan table saw from an estate. The saw was in the process of being restored, motor was rewound, but no control transformer, starter has a 110v coil. It was still...