    It looks like that in that Mode5 the control is...

    It looks like that in that Mode5 the control is telling the X axis to move for some reason, that is what that 1.25V is on those leads, and if I understand what you did previously, then the Bosch...
  2. Replies
    31
    Views
    1,543

    that signal is DC, 0V means the control doesn't...

    that signal is DC, 0V means the control doesn't want to move that axis, positive or negative voltage means the control tells to run the motor in forwards or backwards and how fast, the higher the...
  3. Replies
    31
    Views
    1,543

    there should be a diagram on the Bosch drive,...

    there should be a diagram on the Bosch drive, looks like this:
    299791

    X11 X21 X31 are the axis, pins 1 and 2 on each are the input signals from the control, disconnect those wires from the X11...
  4. Replies
    31
    Views
    1,543

    Have you checked voltage on the Bosch drive +/-...

    Have you checked voltage on the Bosch drive +/- 10V inputs? With the wires from the Dialog connected and disconnected, to see where the command to move comes from