    Schematic for machine in Senior Moment. Can't rem eber what this device is called.

    I can't seem to find a definite definition for the zig-zag line symbol in several places.

    For instance, the drive motor start circuit, lower middle left, shows this zig-zag symbol to the left of the L6 pilot light. What the hell does this signify?

    dscf1072.jpg

  2. #2
    Join Date
    Dec 2017
    Country
    UNITED STATES
    State/Province
    New York
    Posts
    204
    Post Thanks / Like
    Likes (Given)
    43
    Likes (Received)
    76

    Default

    It's a coil for a magnetic starter most likely.

    Ted

  3. Likes Oilyneil liked this post
  4. #3
    Join Date
    Jun 2001
    Location
    St Louis
    Posts
    19,330
    Post Thanks / Like
    Likes (Given)
    2403
    Likes (Received)
    3652

    Default

    That seems to be the case, although it would not be standard in my world......

    Some of them, labeled "RT" and a number, have contacts shown elsewhere on the schematic.

  5. #4
    Join Date
    Oct 2010
    Country
    UNITED STATES
    State/Province
    Oregon
    Posts
    5,746
    Post Thanks / Like
    Likes (Given)
    5660
    Likes (Received)
    2204

    Default

    RT makes me think thermal overload cutouts (aka "heaters"). R (and also the zigzag) for resistor, T for thermal.

  6. Likes JST liked this post
  7. #5
    Join Date
    Jun 2001
    Location
    St Louis
    Posts
    19,330
    Post Thanks / Like
    Likes (Given)
    2403
    Likes (Received)
    3652

    Default

    Agree that was definitely indicated for some, but others, well they just don't seem to fit, like the one the OP asked about.

    I've seen that in really ancient schematics, like from the 1930s, where resistors were rectangular blocks, and coils were zig-zag like that.

  8. #6
    Join Date
    Oct 2010
    Country
    UNITED STATES
    State/Province
    Oregon
    Posts
    5,746
    Post Thanks / Like
    Likes (Given)
    5660
    Likes (Received)
    2204

    Default

    I'd agree that zig-zags 6, 6A, 6I, and 6P are the coils for the relays whose contacts are marked 6, 6A, 6I and 6P.

    I think 6EM is a control relay to convert a momentary pushbutton contact into a sustained "on", with a side order of EMergency stop functionality, but I think it's sort of bad practice to combine emergency stop with pushbutton sustain that way.

  9. #7
    Join Date
    Dec 2019
    Country
    NEW ZEALAND
    Posts
    406
    Post Thanks / Like
    Likes (Given)
    31
    Likes (Received)
    94

    Default

    Resistors being rectangular blocks is EU/IEC standard, along with relay coils.

  10. #8
    Join Date
    Jun 2001
    Location
    St Louis
    Posts
    19,330
    Post Thanks / Like
    Likes (Given)
    2403
    Likes (Received)
    3652

    Default

    Quote Originally Posted by SomeoneSomewhere View Post
    Resistors being rectangular blocks is EU/IEC standard, along with relay coils.

    Two different things of same symbol is bad.

  11. #9
    Join Date
    Mar 2017
    Country
    LATVIA
    Posts
    841
    Post Thanks / Like
    Likes (Given)
    235
    Likes (Received)
    483

    Default

    you can't mistake one for the other, resistor rectangle is always skinny with wires coming to the narrow ends, relay rectangle is fat and wires connect to the long sides

    as for the OP, it seems to be thermal/overload protection, once the 2 are open, the 3rd wire will not be connected to anything so no current can flow and doesn't need protection on it:
    thermal-prot.jpg

    edit, I was wrong, not thermal, but seems to be something like NC relay contacts

    edit2, another description:
    zigzag.jpg

    edit3, found another one, still under US/CAN symbols - magnetic overcurrent relay, so overcurrent breaks the NC contact presumably

    https://forums.autodesk.com/autodesk...20DIAGRAMS.pdf

  12. #10
    Join Date
    Feb 2006
    Location
    Republic of Texas
    Posts
    2,930
    Post Thanks / Like

    Default

    The machine is Italian from the mid 70's. I am beginning to think that the schematics are not for this machine.

    Very few of the wire numbers on machine match the schematics. 66# and 67# do match and they go to the E-stop (6EM) button.

    I'm wondering if the RT designate heaters as the RT1, RT2 seem to match the two remotely mounted heaters, middle, far right. The output of them is U and V respectively.

    Coils for starters are 120v.

    Large starter at bottom is for the spindle and oil pump. Starters above that are rapid forward, rapid reverse,and coolant pump. To the right of them is a 4 pole single throw relay.

    The large starter only has 2 heaters. Seems a bit odd to me.

    dscf1073.jpg

  13. #11
    Join Date
    Mar 2017
    Country
    LATVIA
    Posts
    841
    Post Thanks / Like
    Likes (Given)
    235
    Likes (Received)
    483

    Default

    they would be more like modern resettable fuses, they have 2 components in them - a thermal and magnetic, thermal will trip on light/long overload, magnetic will actuate instantly and disconnect the circuit - and that is what you have marked as RT1 through RT4, not sure how it looks physically, but the way they work is - unless they are tripped, they stay closed, and if there is a short in the circuit (motor coil insulation failure for instance), it will create an instant overload > and the electromagnetic actuator will break the circuit, it is necessary only on 2 of the 3 phases, since when you break 2 of the 3 wires coming to that motor - no current can flow

    p.s. red box around the part we were discussing in the other thread, FR being the mystery device, and if it is, then you indeed had an error in your drawing or the wiring has been altered, you had the top wire going to "0" loop back on the NO 6EM contacts, when it should have went back to the transformer like I suggested never mind this - I see that it goes back to "0" via another 6EM contact group
    capture.jpg

  14. #12
    Join Date
    Mar 2011
    Location
    Geneva Illinois USA
    Posts
    6,565
    Post Thanks / Like
    Likes (Given)
    2942
    Likes (Received)
    2634

    Default

    This is typical of older European electrical diagrams. Very confusing to US electricians.

    Tom

  15. Likes CarbideBob liked this post
  16. #13
    Join Date
    Feb 2006
    Location
    Republic of Texas
    Posts
    2,930
    Post Thanks / Like

    Default

    Quote Originally Posted by jz79 View Post
    they would be more like modern resettable fuses, they have 2 components in them - a thermal and magnetic, thermal will trip on light/long overload, magnetic will actuate instantly and disconnect the circuit - and that is what you have marked as RT1 through RT4, not sure how it looks physically, but the way they work is - unless they are tripped, they stay closed, and if there is a short in the circuit (motor coil insulation failure for instance), it will create an instant overload > and the electromagnetic actuator will break the circuit, it is necessary only on 2 of the 3 phases, since when you break 2 of the 3 wires coming to that motor - no current can flow
    I think we are talking about the same device. In the USA most people refer to the overloads as "heaters"

    FWIW, in a previous life I was a licensed industrial/commercial electrician. Some of the symbols in this schematic have thrown me for a loop as they don't look like any that I recall seeing before...

  17. #14
    Join Date
    Oct 2010
    Country
    UNITED STATES
    State/Province
    Oregon
    Posts
    5,746
    Post Thanks / Like
    Likes (Given)
    5660
    Likes (Received)
    2204

    Default

    Quote Originally Posted by alphonso View Post
    The large starter only has 2 heaters. Seems a bit odd to me.
    Nah. Adding a third heater would add value only if you expect the heater to be the thing that catches shorts to ground. (And that's not what heaters are for.) Assuming no shorts, any current through the motor has to pass through two of T1/T2/T3. So two heaters are sufficient to catch overload currents.

  18. Likes JST, neilho liked this post
  19. #15
    Join Date
    Feb 2006
    Location
    Republic of Texas
    Posts
    2,930
    Post Thanks / Like

    Default

    Finally figured out what the zigzag symbol is. Heaters/overload integral to the motor starters, one of which is a NC contact well hidden behind the usual heater assembly.

    dscf1080.jpg

    Hidden contact lower left of starter. #3 wire is daisy chained to all the starters.

  20. #16
    Join Date
    Aug 2004
    Country
    UNITED STATES
    State/Province
    California
    Posts
    2,793
    Post Thanks / Like
    Likes (Given)
    30
    Likes (Received)
    694

    Default

    The zig-zags in the POWER circuit would have been the heater elements (coils). The zig-zags in the CONTROL circuit would be the solenoid coils. That's an old European standard prior to the "harmonization" of IEC standards in the late 70s / early 80s. I worked for a German company (Klockner Moeller) at that time, we used those symbols on equipment drawings we made here because "Zat ist de vay you vill do it!", but we were constantly having to explain it to people here in the US.

  21. Likes Yan Wo, CarbideBob liked this post
  22. #17
    Join Date
    Feb 2006
    Location
    Republic of Texas
    Posts
    2,930
    Post Thanks / Like

    Default

    Quote Originally Posted by Jraef View Post
    The zig-zags in the POWER circuit would have been the heater elements (coils). The zig-zags in the CONTROL circuit would be the solenoid coils. That's an old European standard prior to the "harmonization" of IEC standards in the late 70s / early 80s. I worked for a German company (Klockner Moeller) at that time, we used those symbols on equipment drawings we made here because "Zat ist de vay you vill do it!", but we were constantly having to explain it to people here in the US.

    So, what you are saying is that all the zigzags in the control side of the schemati9cs are the coils in the motor starters?

    As I continue to trace wires down, I get more confused. Most of the (few) wire numbers in the schematics do not match the machine numbers.

    And all this started because none of the lights on the machine worked when I got the machine. At this point, the only light that works is the 24v on the far left of schematic. It is simply an indicator that the power is on.


  23. #18
    Join Date
    Jan 2007
    Location
    Flushing/Flint, Michigan
    Posts
    10,578
    Post Thanks / Like
    Likes (Given)
    619
    Likes (Received)
    8547

    Default

    Here is a novel approach.
    Act as if you have no schematic or prints, track down wires and draw your own.
    Bob

  24. #19
    Join Date
    Feb 2006
    Location
    Republic of Texas
    Posts
    2,930
    Post Thanks / Like

    Default

    Quote Originally Posted by CarbideBob View Post
    Here is a novel approach.
    Act as if you have no schematic or prints, track down wires and draw your own.
    Bob

    Which I have been doing. Trying to isolate each circuit as i go. Have about 15 pages so far. It hasn't helped that at some point in the past, the wires in the carriage were replaced and a whole new set of numbers attached to the new wires. WTF.

    In the schematic above there is a symbol at the bottom of the "rapid motor" that has me puzzled. Symbol is circle with FR in it. Traced the FR wire to the carriage where it disappears into the interior of the apron.

  25. #20
    Join Date
    Oct 2010
    Country
    UNITED STATES
    State/Province
    Oregon
    Posts
    5,746
    Post Thanks / Like
    Likes (Given)
    5660
    Likes (Received)
    2204

    Default

    Quote Originally Posted by alphonso View Post
    So, what you are saying is that all the zigzags in the control side of the schemati9cs are the coils in the motor starters?
    It's what I concluded back in post #6, if we are talking about the same zigzags.