What is the CNC rated to pull? If there is both a full load and an idle rating, give both.
Where are you measuring? The RPC has one wire that it powers, and two that are "passed through" from the power line. If you measure the "pass thru" line that goes to the actual idler motor (but not onto the CNC) , you will read a different current than if you measure one of the incoming power lines so that you get both the current to the RPC and the current to the CNC.
What size motor is actually in the RPC? AD20 at 20 HP rating likely has a 30 HP motor.
The CNC is rated at a max load of 10kVa and my main supply voltage is 222 volts. The mill's 3 axes motors are 5.5amps max and the spindle motor is 17amp continuous or 25amp for 15mins.
I'm measuring each line individially. The 40amp draw I'm reporting is roughly what most of the 3 measurements were... look lower in my response here for the exact measurements on all three lines.
The idler motor has a 20hp badge on it.
Hmm. wonder what's happening here. 40 X 240 X 1.7 = 16 KW.
Probably something in the machine is getting *really* hot there. Is it water-cooled?
I ran the cnc machine at idle for 5mins with the 40 amp draw. I checked the temp by hand of all 4 motors and nothing is getting hot. I also held the power cables for the 4 drives in my hand and none were hot.
New stuff I learned/measured,
-I moved the input wires around on the terminals and have new voltages across legs and the high amp draw is still present
T1-T2: 222v
T1-T3: 205v
T2-T3: 239v
-The high amp draw is seen on the supply lines to the cnc’s built in disconnect, on the wires on the other side of the disconnect and in the wires going into the controller box. The controller box does not get hot.
-The power lines from the controller to the drives are also not hot and measure zero amps with the machine at idle.
-The amp readings in the 3 supply lines vary line to line. I’ve been reporting the 40amps as a high average. The actual readings are,
T1: 51a
T2: 42a
T3: 34a (this is the wild leg)
-Is it strange that these are all different? Does it possibly indicate anything off/broken in the phase converter panel or the idler itself?
-The main supply wires are getting warm, but just barely noticeable. They are 8awg.
-The ground line shows no current
-When the machine e-stop is engaged the draw on every line drops to less than 1amp.
-The Fanuc tech I talked to said that some of these generation machines (this one is from 2007) would "dump" voltage if it sees something out of spec. I wonder if the initial high voltage of 239v is putting the machine into a mode that starts to "dump" voltage. I'm not familiar with this... is there a device that can even do this without current being picked up on the ground wire?
Any other ideas out there? The responses and help so far is much appreciated!