What's new
What's new

Mazak Mitsubishi transformer questions

cgmaster

Cast Iron
Joined
Jun 9, 2008
Location
Ocean Springs, MS
I am installing another Mazak lathe and comparing the electrical drawings and the transformer the taps don't match up. I believe the transformer is original to the machine.

The drawing say to connect
1-4
5-8
9-10
11-12

unfortunately the actual taps only go to 8. The transformer is a model kt-4217. See photos

I am Curtis if I can try different taps without hurting anything. This is on a Integrex 200sy and I am connecting to 240v.

20180127_131658.jpg20180127_131647.jpg20180127_131658.jpg20180127_131647.jpg
 
Hey Curtis,

Just wondering if you ever figured out the tap locations? I am having the same issue with my Integrex.

Thanks, Josh
 
Hey Curtis,

I keep trying to PM you with my email address but it dosen't seem to be going through, are you getting them?

Thanks, Josh
 
Got this wiring diagram today from a friend and thought I would post it in case anyone else has this issue in the future. Mazak Integrex 100 Transformer taps wiring diagram.jpg
 








 
Back