Guys,

I bought this Italian press at auction (online) in Surrey, BC.

There is no name plate information.
The motor data is 380wye/220delta 50 Hertz.

From my reading 60 Hertz is standard in Canada.
In the control cabinet there's a small tformer.

From the attached pictures can guys interpret how this is wired?
I have had no luck in learning how the shop was wired in Canada. The owner is overseas on holiday.

I'm not sure if this tformer is stepping down the 480 to run the press near the 380 nameplate voltage.

Thanks,

Tom
72418cdefefbd8db38d8370860a5bdde.jpg
3345b82dd31d238ea79062f67fee654c.jpg
9fac1bcb1b38bf588601721160158487.jpg
c6c1465b696c189358a62bcd7b7ec342.jpg
0dbc312a6445a0e7da3d7c60ad0177e5.jpg
1a133af6752a483b3b7c4a63ba4636b3.jpg


Sent from my SM-G960U1 using Tapatalk
 
Many such coils have the voltage they need printed on them in plain sight - which will be what the transformer is putting out currently
 
The control transformer is wired for 480V input, and 120V output for the controls.

The motor is likely wired for 380V input, but powered at 480V 3Φ 60Hz.

Motor will run fine at 480V 60Hz, but run at 20% faster than rated speed for 50Hz.

SAF Ω
 
The control transformer is wired for 480V input, and 120V output for the controls.

The motor is likely wired for 380V input, but powered at 480V 3Φ 60Hz.

Motor will run fine at 480V 60Hz, but run at 20% faster than rated speed for 50Hz.


SAF Ω



Hello SAF Ω

This is what I was hoping to find out.

Thank you guys for the help!!!

Tom
 








 
Back