Hello Folks, installing a VFD for the first time and want a sanity check, as well as a question on a command/setting detail.
I need 3 phase for a 20' planer. It uses an ABB motor: M2QA112M4A: 4 pole inductive motor, 230V, 14.41 FLA, 4KW (5.4 hp).
I devined (largely through threads on this forum) that a Frenic-Mini FRN0033C2S-2 should work well.
Initially I will use the stop/run switches on the control panel. Eventually add in fwd/rev/stop on a remote type cable (similar to an overhead crane type control).
Feeding it with 240v @30A.
What I [think] I want it to do is soft start my planer and then let it coast down when shut off. Nothing special, no brakes, no speed control, etc.
Of course it turned out the manual (CD) and installation guide were for a smaller model. Found several versions of the manuals online, used this one: https://americas.fujielectric.com/files/24A7-E-0023d.pdf?r=false
Basic settings that seemed important (not command or work related):
Motor type: (default) F10=1
230v (delta) (default) F06=230
60hz (default) F03=60
Restart after power off (default=trip) F14=0
Horse power (default= P99; HP vs KW) 5.4 & H03=1 & P02=5.4
Functional settings (had to call them something).
Front panel run/stop (default) F02=2
Soft start (default of 6 seconds) F07=6
Cost to stop (default, F08 & E11=6 seconds)F08 & E11 = 0, H11=1
--Need to confirm that H11 setting change negates (or not) F08 & E11 settings
Torque boost (default: F37= constant torque load & F09=100% of starting torque)
--Seem correct?
Also, read a reference (somewhere) that called for turning off 'missing phase' alarm setting.
--I couldn't find that in the command list, and have powered the unit up (no load) with no apparent problem.
Thanks for taking a look at this and responding. I have yet to program these settings in, as I didn't want to hurt anything.
I need 3 phase for a 20' planer. It uses an ABB motor: M2QA112M4A: 4 pole inductive motor, 230V, 14.41 FLA, 4KW (5.4 hp).