split phase motor issues
Close
Login to Your Account
Results 1 to 11 of 11
  1. #1
    Join Date
    Aug 2004
    Location
    ventura,ca.usa
    Posts
    349
    Post Thanks / Like
    Likes (Given)
    1
    Likes (Received)
    45

    Default split phase motor issues

    Hello all, 1/4 hp carbonator type motor on a TIG cooler won't start intermittently. Might work 50 times in succession, not on the 51st. might work 3 times not start the fourth. Well oiled, centrifugal switch has no issues that I can see, it does not appear to occur in the same place on the armature when it comes to a stop, if I turn the armature slightly sometimes it will start sometimes it won't and I have to turn it more then it will. There is a new motor being purchased in the interest of reliability,but I sure hate not being able to figure it out and would appreciate any thoughts or suggestions. Thanks, Jim

  2. #2
    Join Date
    Dec 2010
    Location
    Mifflintown, PA 17059
    Posts
    1,645
    Post Thanks / Like
    Likes (Given)
    18
    Likes (Received)
    170

    Default

    I assume that you saying it's split phase you do not have a capacitor. You say the centrifugal switch works fine but is it making contact? Often wiring is needed to determine rotation, are the start winding connections good or could they be loose and arcing?

  3. Likes hermetic liked this post
  4. #3
    Join Date
    Aug 2004
    Location
    San Ramon, CA USA
    Posts
    2,655
    Post Thanks / Like
    Likes (Given)
    24
    Likes (Received)
    589

    Default

    If it can start after moving it, I would suspect that one of the rotor bars has a break somewhere, usually at the end ring. Not really worth fixing on something that small.

  5. #4
    Join Date
    Jul 2011
    Location
    East Yorkshire UK
    Posts
    327
    Post Thanks / Like
    Likes (Given)
    774
    Likes (Received)
    267

    Default

    try cleaning the contacts on the centrifugal switch, sound like they may be closed, but not making contact electrically, common problem.

  6. #5
    Join Date
    Mar 2011
    Location
    Geneva Illinois USA
    Posts
    5,770
    Post Thanks / Like
    Likes (Given)
    2377
    Likes (Received)
    2224

    Default

    From the description, I am not sure if he has a universal or capacitor start motor.

    Tom

  7. #6
    Join Date
    Aug 2004
    Location
    ventura,ca.usa
    Posts
    349
    Post Thanks / Like
    Likes (Given)
    1
    Likes (Received)
    45

    Default

    Hello all, I have not opened it up to delve into its guts, I suspect something open, but as was said above it is not really economical to fix if it is a break somewhere.(which I really hate, but what do you do?) It must be considered a universal since there are no caps, it is an Emerson S55NXNSM-7296, no bearings,just oil type bushings that I had hoped were the issue but weren't,once I get it apart i'll check the centrifugal switch and look for any obvious signs of opens . Appreciate the feedback so far. Thanks, Jim P.S., jraef, is that a picture of Nikola as a young man?

  8. #7
    Join Date
    Jul 2014
    Location
    MI USA
    Posts
    854
    Post Thanks / Like
    Likes (Given)
    194
    Likes (Received)
    354

    Default

    Typical carbonator pump is split phase with no cap.
    Could also be a problem with the overload protector snap disc control.

    img_20190325_201008785.jpg

    img_20190325_201028452.jpg

    SAF Ω

  9. Likes JST liked this post
  10. #8
    Join Date
    Dec 2010
    Location
    Mifflintown, PA 17059
    Posts
    1,645
    Post Thanks / Like
    Likes (Given)
    18
    Likes (Received)
    170

    Default

    I seen in the photo it states Non-Reversible, are you sure it Split phase? It could be shaded pole. Are you sure it has a centrifugal switch?

  11. #9
    Join Date
    Aug 2004
    Location
    ventura,ca.usa
    Posts
    349
    Post Thanks / Like
    Likes (Given)
    1
    Likes (Received)
    45

    Default

    pictures are not of the motor I have. since it says "split phase" on the nameplate and does not have a cap housing and I can hear the centrifugal switch releasing, I am reasonably sure that it is what it says...

  12. #10
    Join Date
    Mar 2011
    Location
    Geneva Illinois USA
    Posts
    5,770
    Post Thanks / Like
    Likes (Given)
    2377
    Likes (Received)
    2224

    Default

    The type you refer to is called a split phase motor. It uses the resistance of the start winding to shift the phase enough to get the motor started. These have very little starting torque. The most likely problem is the starting switch followed by a break in the start winding.

    Tom

  13. #11
    Join Date
    Aug 2004
    Location
    San Ramon, CA USA
    Posts
    2,655
    Post Thanks / Like
    Likes (Given)
    24
    Likes (Received)
    589

    Default

    If it were a break in the starting winding or the centrifugal switch not closing, moving it slightly would not overcome the inability to start. That's why I was thinking a broken rotor bar, because if it stops where the bad bar happens to line up with the initial pole that gets energized first, it fails to develop enough torque to move the rotor. Rotating it by hand moves it enough to get it to a better spot so it can generate more torque.