    Default TECO L519 "OU-C" error

    After I increased the max freq to 100, and reduced the accel and decel time to 2 seconds, every so often when going from running to stop position on the FNR lever, I get an "OU-C" error. I cannot find this error thru google or in the my manual

    UPDATE: This resulted from too short decel time. It IS in the manual pdf but not searchable!


    ou-fault.jpg

    ou-c-error-teco.jpg

  2. #2
    Join Date
    Aug 2004
    Country
    UNITED STATES
    State/Province
    California
    Posts
    2,763
    Post Thanks / Like
    Likes (Given)
    28
    Likes (Received)
    666

    Default

    Over (O) Voltage (U is voltage) on Constant Speed (C), as opposed to A (Acceleration) or D (Deceleration). It just means you got an Over Voltage condition while you were not accelerating or decelerating. It can happen when your load spins slightly faster than what the drive tells it to.