Thread: Toshiba VF-S15 VFD help
-
11-22-2020, 10:11 PM #1
Toshiba VF-S15 VFD help
Hi guys.
I have just connected a Toshiba S-15 VFD to my Mill which works great but.
The Mill has 2 x built in Momentary switches, 1 to turn on and one to turn off.
I would like to hook them up to the VFD so i can use them to start and stop the Mill but i cannot work out which terminals to
wire them up to and which setting to change.
can anyone help me with this?
-
-
11-22-2020, 10:17 PM #2
I have had very good results looking for operation literature for the several TOSVERT series Toshiba drives I have installed in my shop. Type " Toshiba S-15 manual" into your search engine and see what returns you get.
The connections for momentary switches will be right on the control terminal block
-
11-22-2020, 10:25 PM #3
I do have the manual but i can't seem to understand or see which relates to using external momentary switches..
I have used Allen and bradley vfd's in the past which where easy to understand but the Toshiba seems to be a lot more technical.
-
11-23-2020, 12:34 AM #4
https://www.toshibadrivesandmotors.c...-IO-Manual.pdf
Page G-3. "3-wire operation (one-push operation)".
It looks like you want F-110 = 6.
-