Toshiba VF-S15 VFD help
Close
Login to Your Account
Likes Likes:  0
Results 1 to 5 of 5
  1. #1
    Join Date
    Oct 2020
    Country
    AUSTRALIA
    Posts
    18
    Post Thanks / Like
    Likes (Given)
    4
    Likes (Received)
    0

    Default Toshiba VF-S15 VFD help

    Hi guys.

    I have just connected a Toshiba S-15 VFD to my Mill which works great but.

    The Mill has 2 x built in Momentary switches, 1 to turn on and one to turn off.

    I would like to hook them up to the VFD so i can use them to start and stop the Mill but i cannot work out which terminals to
    wire them up to and which setting to change.

    can anyone help me with this?

  2. #2
    Join Date
    Dec 2008
    Location
    Vt USA
    Posts
    8,894
    Post Thanks / Like
    Likes (Given)
    1472
    Likes (Received)
    3154

    Default

    I have had very good results looking for operation literature for the several TOSVERT series Toshiba drives I have installed in my shop. Type " Toshiba S-15 manual" into your search engine and see what returns you get.

    The connections for momentary switches will be right on the control terminal block

  3. #3
    Join Date
    Oct 2020
    Country
    AUSTRALIA
    Posts
    18
    Post Thanks / Like
    Likes (Given)
    4
    Likes (Received)
    0

    Default

    I do have the manual but i can't seem to understand or see which relates to using external momentary switches..

    I have used Allen and bradley vfd's in the past which where easy to understand but the Toshiba seems to be a lot more technical.

  4. #4
    Join Date
    Dec 2019
    Country
    NEW ZEALAND
    Posts
    262
    Post Thanks / Like
    Likes (Given)
    1
    Likes (Received)
    55

    Default

    https://www.toshibadrivesandmotors.c...-IO-Manual.pdf

    Page G-3. "3-wire operation (one-push operation)".

    It looks like you want F-110 = 6.

  5. #5
    Join Date
    Oct 2020
    Country
    AUSTRALIA
    Posts
    18
    Post Thanks / Like
    Likes (Given)
    4
    Likes (Received)
    0

    Default

    Quote Originally Posted by SomeoneSomewhere View Post
    https://www.toshibadrivesandmotors.c...-IO-Manual.pdf

    Page G-3. "3-wire operation (one-push operation)".

    It looks like you want F-110 = 6.
    Thank you so much.. I would have never found that..

    I will give ut a try tomorrow..